Our automatic counting machine for packaging system has a fault alarm function, and the corresponding fault is displayed through the alarm lamp and the display screen, and will automatically stop according to the alarm situation. If this happens,please eliminate it according to the method described in the following table. If it still cannot be eliminated, please send someone to deal with it immediately. Except for the computer control system, users of general faults can all be eliminated.
Failure phenomenon |
The reason |
Elimination method |
The whole machine is not powered on after pressing the power button |
Due to the large instantaneous current of the whole machine, the MCB protection |
Clockwise rotate the emergency stop button to make the button pop up, use the factory-configured special key to open the electrical cabinet and push on the corresponding MCB |
The backlight does not light up after power on |
The background LED light bar is burned out or the background light wiring is faulty |
Contact the manufacturer to replace the background LED light and wiring |
The display shows background abnormal alarm |
There is a foreign object at the point of view causing an abnormal background |
Check whether there are foreign objects blocking the viewpoint near the viewpoint, and it can work normally after eliminating the interference of foreign objects |
After setting the preset number of packages normally, click Start counting and the preset number of packages is 0 |
Misoperation leads to abnormal encryption process of the whole machine |
Turn off the display and restart the whole machine |
Vibrator does not work |
The vibrator is damaged or the control line of the vibrator is faulty |
contact the manufacturer to replace the vibrator and check the vibrator control circuit |
The display shows the abnormal alarm of the packaging machine |
A certain link in the packaging machine process fails |
Troubleshoot the fault according to the packaging machine manual, and clean up the materials currently being counted, and continue to work after the packaging machine is troubleshooting |
The display shows lack of material |
The counting machine has no material supply for a long time |
Check the feeding circuit and resume normal feeding |
The software interface shows communication abnormality |
Counting machine communication network fluctuation |
Turn off the monitor and restart the whole machine |
The count interface does not appear on the display |
The counting software was closed by mistake |
Double-click the shortcut of XCounter.exe on the desktop to restart the program |